General Introduction
MYSC-L Solar Intelligent Lighting Controller is a new product with optimized design which adopted advanced microcomputer chip and innovative control circuit and has excellent performance, reliable quality. It is a multifunction, multi-role controller which specially designed for all kinds of solar street lamps or household solar power lighting system.
Design Features
1、 To the instability of solar charge and the battery’s discharge curve , we designed the professional charging and discharging circuit, thereby implement intelligent control of the whole system.
2、 Utilize the amendatory battery’s discharge rate for battery discharge control. Discharge terminated voltage is control point amended by discharge rate curve, which eliminate the inaccuracy of mere voltage controlled over discharge, and it accord with the inherent characteristics of battery, that is , different discharge rate has different terminated voltage, consequently ensure the effective use of the battery.
3、 Full automatic control such as overcharge protection, over discharge protection. Protections above won’t cause damage to any component.
4、 Dual voltage automatic identification, Can be used for 12V system and 24V system, can identify working system automatically once connected to the battery.
5、 Visual LED luminotron indicate the system running condition, which allows users to understand operating condition.
Technical Parameters
|
Model |
MYSC-L205 |
MYSC-L210 |
MYSC-L215 |
|
Rated charging current |
5A |
10A |
15A |
|
Overload protection current |
5A |
10A |
15A |
|
Load short-circuit protection current |
10A |
15A |
20A |
|
System voltage |
12V/24V |
|
Overall dimension(mm) |
103(L)×91(W)×36.7(H) |
|
Overload delay time |
5A/ >10 seconds |
10A/ >10 seconds |
15A / >10seconds |
|
Light-operated switch on/off delay time |
5 seconds |
5 seconds |
5 seconds |
|
No-load loss |
≤30mA |
|
Discharge circuit voltage drop |
≤0.15V(40W/24V output )
Remark: cable loss excluded |
|
Operating temperature |
Technical grade:-35℃to +55℃ |
|
Low voltage |
11.1V±0.2V /22.1V±0.3V |
|
Over discharge terminated voltage |
12.5V±0.3V /25.6V±0.3V |
|
Fully charged voltage data |
14.3V±0.3V /28.5±0.3V |
|
Overvoltage data |
15V±0.5V /30V±1V |
|
Extra high voltage protection data |
3 3V |
|
L1 Load control mode |
Light-operated+ time control(factory reset) |
|
L2 Load control mode |
Light-operated only(factory reset) |
|
Light-operated switch-on voltage |
Solar panel voltage1.8V±0.2V
Solar panel voltage3.6V±0.4V |
|
Reset |
Press the reset button for more than 15 seconds |
|
Protection Degree |
IP54 |