中文版 ┊ English
 
Business
 
MYSC-L205

General Introduction

MYSC-L Solar Intelligent Lighting Controller is a new product with optimized design which adopted advanced microcomputer chip and innovative control circuit and has excellent performance, reliable quality. It is a multifunction, multi-role controller which specially designed for all kinds of solar street lamps or household solar power lighting system.

 

Design Features

1、   To the instability of solar charge and the battery’s discharge curve , we designed the professional charging and discharging circuit, thereby implement intelligent control of the whole system.

2、    Utilize the amendatory battery’s discharge rate for battery discharge control. Discharge terminated voltage is control point amended by discharge rate curve, which eliminate the inaccuracy of mere voltage controlled over discharge, and it accord with the inherent characteristics of battery, that is , different discharge rate has different terminated voltage, consequently ensure the effective use of the battery.

3、   Full automatic control such as overcharge protection, over discharge protection. Protections above won’t cause damage to any component.

4、   Dual voltage automatic identification, Can be used for 12V system and 24V system, can identify working system automatically once connected to the battery.

5、   Visual LED luminotron indicate the system running condition, which allows users to understand operating condition.

 

Technical Parameters

Model

MYSC-L205

MYSC-L210

MYSC-L215

Rated charging current

5A

10A

15A

 Overload protection current

5A

10A

15A

Load short-circuit protection current

10A

15A

20A

System voltage

12V/24V

Overall dimensionmm)

103(L)×91(W)×36.7(H)

Overload delay time

5A/ >10 seconds

10A/ >10 seconds

15A / >10seconds

Light-operated switch on/off delay time

5 seconds

 5 seconds

 5 seconds

No-load loss

≤30mA

Discharge circuit voltage  drop

≤0.15V40W/24V output

Remark: cable loss excluded

Operating temperature

Technical grade-35to +55

Low voltage

11.1V±0.2V /22.1V±0.3V

 Over discharge terminated voltage

12.5V±0.3V /25.6V±0.3V

Fully charged voltage data

14.3V±0.3V /28.5±0.3V

Overvoltage data

15V±0.5V /30V±1V

Extra high voltage protection data

3 3V

L1 Load control mode

 Light-operated+ time control(factory reset)

L2 Load control mode

Light-operated only(factory reset)

Light-operated switch-on  voltage

Solar panel voltage1.8V±0.2V

Solar panel voltage3.6V±0.4V

Reset

Press the reset button for more than 15 seconds

Protection Degree

IP54

 
  HOME CONTACT   Top  